CHAPTER 11. AIRCRAFT ELECTRICAL SYSTEMS
11-17. BATTERY FREEZING. Discharged lead-acid batteries exposed to cold tempera-tures are subject to plate damage due to freez-ing of the electrolyte. To prevent freezing damage, maintain each cell''s specific gravity at 1.275, or for sealed lead-acid batteries check “open” circuit voltage. (See table 11-1.) Ni-